Model 4821/4820 Control/Communicator Installation Manual
6-16 150966
6.3.2 Partition List and Menus
When you select to Add or Edit a partition from the System SubMenu, a list of partitions dis-
plays. Choose the partition you want to edit or select Add to create a new partition. Once you
select Add or Edit, a screen displays the partition options menu system. The subsections that
follow describe these options in detail.
6.3.2.1 Partition Options Screen
Option Description Default
Partition Name Enter up to 16 characters to name or describe the partition you are
adding. When you choose to add a new or edit an existing partition,
the partition options screen (see below) displays.
Partition 1
(- Partition 8)
Table 6-5: Partition Options and Description
Option Description Default
Automatic Disarm on Door
Access
If enabled, all areas within the partition that the user has access to will
automatically disarm when door access is granted to a valid user. The
option is available only for users who have the ability to disarm.
Disabled
Delayed Zones Instant on
Intrusion
If this option is enabled, all exit and entry delayed zones will be instant
whenever an alarm occurs in an intrusion zone. This will not occur for
other types of zones.
Disabled
Interior Zones Active on In-
trusion
If this option is enabled, all interior zones will activate automatically
whenever an intrusion alarm occurs in an intrusion zone. This will not
occur for other types of zones.
Disabled
Interior and Delay States
Locked when Armed
If this option is enabled, users must disarm the system if they want to
change the interior and delay states. Typically used to prevent unau-
thorized persons from deactivating interiors when the system is
armed.
Disabled
Unbypass on Disarm If this option is enabled, any zones that were bypassed since the last
disarming period will be unbypassed (reinstated) when the system is
disarmed. The unbypassing operation will not occur if it would cause
an alarm or trouble.
This feature prevents users from leaving a zone bypassed indefinitely
if they forget that a zone was bypassed temporarily for a special situ-
ation.
Enabled
Deactivate Interior Zones
on Disarm
If this option is enabled, interior zones assigned to areas within this
partition are deactivated when the areas are disarmed.
Disabled
Activate Interior Zones on
Arm
If this option is enabled, interior zones assigned to areas within this
partition are automatically activated when the areas are armed.
Disabled
Comentários a estes Manuais