Installation Instructions
151174 3-3
3.1.3.4 AC Power Input Terminals
The AC power input terminal are used to connect the AC transformer to the control panel. See
Section 3.5.2 for AC transformer wiring instructions.
3.1.3.5 Door and Auxiliary Relay Terminals
The door and auxiliary relay terminal can be used to connect a AC or DC door strike which is
control by the control panel. The maximum allowable draw from a doorstrike is 250 VAC @
1A.
3.1.3.6 The Door and Auxiliary Reset Terminals
The Door and Auxiliary Reset Terminals are used to connect a door reset switch to the control
panel. See Section 3.5.10 for more information.
3.1.3.7 SBUS Terminals
The SBUS terminals are used to connect satellite units to the master control unit in a system.
See Section 3.5.7 for more information.
3.1.3.8 Phone line Terminals
The phone line terminals are used to connect the system phone line to the control panel. See
Section 3.5.11 for more information.