Series 5000 Entry System Installation/Operation Manual
4-4 151174
11. Press any key other than * or # to toggle between yes or no.
12. Press *. The display shows HIDE CODES ?
YES or NO.
YES = Hide access & keyless entry codes while entering them
NO = Show access code & keyless entry code while entering them
13. Press any key other than * or # to toggle between yes or no.
14. Press *. The display shows * BEFORE 6
YES or NO
YES = visitor must press * before tenant can open door by pressing 6.
NO = tenant just needs to press 6.
This feature is used to prevent unauthorized entry using a TouchTone beeper to activate
doorstrike.
15. Press any key other than * or # to toggle between yes or no.
16. Press *. The display will show PBX ACCESS #
XX. X = a number from 0-9.
17. Enter the number (up-to two digits) necessary to access a PBX system.
This may be necessary for phone lines that are run through a PBX system.
18. Press *. The display shows USER # LENGTH
X.
X = a number from 1-8 which is the number of digits to be used on the user directory.
19. Enter 1, 2, 3, or 4 depending on the number of digits to be used on the user directory.
20. Press *. The display shows CALL LENGTH
1-255.
This is how much time is allowed between the time the system is finished dialing and the
time it automatically hangs-up, 1-255 seconds.
21. Enter the Call Length time.
22. Press *. The display shows DOOR TIME
1-255.
This selects the length of time (1-255 seconds) the door relay will be activated for entry.
23. Enter the Door Time.
24. Press *. The display shows AUX TIME
1-255
This selects the length of time (1-255 seconds) the auxiliary relay will be activated. If aux
relay is programmed as Alarm or Ground Start, aux time is ignored.
25. Enter the auxiliary relay time.